Inch Size
|
L (inch)
|
L1 (inch)
|
L2 (inch)
|
Z* (inch)
|
Z1** (inch)
|
B (inch)
|
D1 (inch)
|
D2 (inch)
|
H (inch)
|
A (inch)
|
Weight lbs.
|
3/8
|
4.45
|
2.48
|
-
|
2.93
|
3.53
|
0.55
|
1.81
|
-
|
1.97
|
3.07
|
0.33
|
½
|
4.49
|
2.48
|
6.21
|
2.70
|
3.36
|
0.55
|
1.81
|
3.50
|
1.97
|
3.07
|
0.33
|
¾
|
5.18
|
2.95
|
7.01
|
3.15
|
3.93
|
0.74
|
2.20
|
3.88
|
2.36
|
3.62
|
0.55
|
1
|
5.62
|
3.11
|
7.68
|
3.34
|
4.35
|
0.94
|
2.64
|
4.25
|
2.76
|
3.94
|
0.79
|
1¼
|
6.58
|
3.50
|
8.69
|
4.05
|
5.25
|
1.21
|
3.23
|
4.63
|
3.14
|
4.33
|
1.32
|
1½
|
6.76
|
3.74
|
8.86
|
3.98
|
5.20
|
1.53
|
3.86
|
5.00
|
3.62
|
4.72
|
2.05
|
2
|
7.97
|
4.53
|
10.54
|
4.95
|
6.36
|
1.92
|
4.72
|
6.00
|
4.33
|
5.75
|
3.75
|
L = overall length L1 = face to
face (flanged) Z* = solvent cement socket valve (laying length)
Z1** = Threaded valve (laying length is herein
defined as the dimension between the ends of pipe when threaded into valve to a depth
equal to the nominal "Handtight" plus ½ turn)
|
Inch Size
|
X (inch)
|
K (inch)
|
M+N (inch)
|
Min. J (inch)
|
Example: Assume for a 2" valve the
required distance from its centerline to the underside of the handle (j) is 24". Formula:
J-(M+N)=L pipe length
24"-5.39"=18.61" |
3/8
|
0.94
|
0.89
|
3.11
|
4.23
|
½
|
0.94
|
0.89
|
3.11
|
4.23
|
¾
|
1.14
|
1.00
|
3.49
|
4.61
|
1
|
1.34
|
1.08
|
3.86
|
4.98
|
1¼
|
1.67
|
1.12
|
4.26
|
5.38
|
1½
|
1.97
|
1.28
|
4.70
|
5.82
|
2
|
2.41
|
1.52
|
5.39
|
6.51
|